Cylindrical |
|
|
|
|
|
|
|
|
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|
|
|
|
MS-324 Miniature Flat Pack Proximity Sensor
This screw mountable sensor can be mounted with M3 screws and can switch moderate loads of 10W. It is particularly useful in industrial applications where distance adjustments need to be made every now and then. Various activating distances are available depending on the magnet and the AT band used. This sensor can be supplied with non-standard connectors on request. All sensors are tested 100% for operate and release AT, contact resistance and variable contact resistance before packing. Our products are completely Lead-free and conform to the RoHS directive.
|
|
Contact Form |
A |
|
|
Contact Rating (max) |
W / VA |
10.0 |
|
Switching Current (max) |
A |
0.5 |
|
Carry Current (max) |
A |
1.5 |
|
DC Switching Voltage (max) |
V DC |
180 |
|
Breakdown Voltage (min) |
V DC |
200 |
|
Initial Contact Resistance (max) |
mΩ |
150 |
|
Operating Temperature |
°C |
-40 to +70 |
|
Shock Resistance (½Sin wave for 11ms) |
g |
50 |
|
Vibration Resistance (10-2000Hz) |
g |
20 |
MS-324-(Operate AT Code)-(Cable Length in mm)-(Lead Type Code)
| OAT Code | OAT Band | Lead Type Code | |
| 1 | 10 - 15 | S | Stripped to 5 mm |
| 2 | 15 - 20 | T | Stripped and Tinned |
| 3 | 20 - 25 | M | 2-pin Female Molex Connector |
Operate AT bands indicated above are for unmodified reed switch.
MS-324-1-500-M
Denotes MS-324 proximity sensor in 10-15 Operate AT, with 500 mm cable length and Molex connectors.

A few examples of magnet actuation are shown above. Being an omnipolar device, this sensor can be actuated with either a north pole or a south pole or both. Choosing the right AT band, magnet strength, and operating axis, will restrict the number of operates and releases to one. Click here to view actuation distances of this sensor with the standard magnets.
|
|
|
Cylindrical |
|
|
|
|