Ultra Miniature |
|
|
|
|
|
|
|
|
|
||||||||||||||||||||||||||||||||||||||||||||||
|
|
|
|
|
MK-xxxx PCB Mountable Reed Sensor with Integrated Resistor
This reed sensor is built with an internal resistor which can either be used for level sensing applications or for contact protection. A diode can also be put in place of the resistor and the dot marked on the sensor can be used to denote the polarity. Various activating distances are available depending on the magnet and the AT band used. The sensors are tested 100% for operate and release AT, contact resistance and variable contact resistance before packing. Our products are completely Lead-free and conform to the RoHS directive.
|
|
Contact Form |
A |
|
|
Contact Rating (max) |
W / VA |
10.0 |
|
Switching Current (max) |
A |
0.5 |
|
Carry Current (max) |
A |
0.75 |
|
DC Switching Voltage (max) |
V DC |
100 |
|
Breakdown Voltage (min) |
V DC |
150 |
|
Initial Contact Resistance (max) |
mΩ |
150 |
|
Operating Temperature |
°C |
-40 to +140 |
| Shock Resistance (½Sin wave for 11ms) | g | 30 |
| Vibration Resistance (10-2000Hz) | g | 20 |
MK-(Resistor Value)-(Operate AT Code)
| OAT Code | AT Band |
| 1 | 10 - 15 |
| 2 | 15 - 20 |
Resistor value in ordering code refers to standard integrated resistor (1/8 W, 1% tolerance).
Operate AT bands indicated above are for unmodified reed switch.
MK-0120-1
Denotes 10-15 Operate AT, with 120 ohms resistor
Gold plated leads
Different plastic encapsulation

A few examples of magnet actuation are shown above. Being an omnipolar device, this sensor can be actuated with either a north pole or a south pole or both. Choosing the right AT band, magnet strength, and operating axis, will restrict the number of operates and releases to one. A ring magnet can also be used around the sensor, for use in float applications. Click here to view actuation distances of this sensor with the standard magnets.
|
|
|
Ultra Miniature |
|
|
|
|
Reed Relays and Electronics India Limited, 2008