Miniature |
|
|
|
|
|
|
|
|
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|
|
|
|
LV-1925 Reed Switch for Line voltage Switching
The LV-1925 is designed for endurance at switching line voltage loads of 230V AC. Two versions are capable of switching 30W and 60W. The third version is manufactured with specially plated blades for endurance at high current levels and can switch up to 90W. When used with contact protection, direct switching of tungsten filament lamps is possible. This reed switch is completely Lead-free and conforms to the RoHS directive.
Lead FormationsLV-1925 reed switches can be supplied in the standard formations shown below. Do contact us for any other special formations or non-standard bending /forming pitches. More information on these formations and tolerances for the dimensions given below can be found here.
|
| Sub Code |
L |
M |
H |
|
| Operate Range | AT | 20 - 60 | 30 - 50 | 30 - 50 |
| Release Range | AT | 5 - 25 | 10 - 30 | 10 - 30 |
| Contact Rating (max) |
W / VA |
30.0 | 60.0 | 90.0 |
| Switching Current (max) |
A |
0.5 | 0.5 | 0.5 |
| Carry Current (max) |
A |
2.5 | 2.5 | 2.5 |
| DC Switching Voltage (max) |
V DC |
230 | 230 | 230 |
| AC Switching Voltage (max) |
V AC |
230 | 230 | 230 |
| Breakdown Voltage (min) |
V DC |
350 | 350 | 350 |
| Initial Contact Resistance (max) |
mΩ |
100 | 100 | 100 |
| Insulation Resistance (min) |
Ω |
1011 |
1011 |
1011 |
| Capacitance (min) |
Pf |
0.2 |
0.2 |
0.2 |
|
Operate Time (max) |
ms |
1.0 |
|
Bounce Time (max) |
ms |
0.6 |
|
Release Time (max) |
ms |
0.15 |
|
Resonance Frequency |
Hz |
> 2000 |
|
Operating Frequency (max) |
Hz |
300 |
|
Operating Temperature |
°C |
-40 to +200 |
| Shock Resistance (½Sin wave for 11ms) | g | 50 |
| Vibration Resistance (10-2000Hz) | g | 20 |
|
Measurement Test Coil |
717 102 002 |
LV-1925-(Sub Code)-(Start Operate AT)-(Finish Operate AT)
LV-1925-L-26-30
Denotes 30 W contact rating in 26-30 Operate AT band
Lower Static Contact Resistance
Dynamic Contact Resistance Limit
Higher Insulation Resistance
Special Release Limits
Gold plated leads
|
|
|
Miniature |
|
|
|
|
Reed Relays and Electronics India Limited, 2008