Miniature |
|
|
|
|
|
|
|
|
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|
|
|
|
SM-1322 Sub Miniature Reed Switch
This form A reed switch is built with a 2.25 mm diameter glass with a higher wall thickness for better glass to metal seals, and is a good solution for general purpose, high volume applications with a little shock and vibration, such as toys. The centre contact also makes it suitable for coil applications. The three differential ranges available cover a wide range of release AT specific applications. A specially plated contact for 230 VAC line voltage switching is also available. This reed switch is completely Lead-free and conforms to the RoHS directive.
Lead FormationsSM-1322 reed switches can be supplied in the standard formations shown below. Do contact us for any other special formations or non-standard bending /forming pitches. More information on these formations and tolerances for the dimensions given below can be found here.
|
| Sub Code |
L |
M |
H |
AC |
|
| Operate Range | AT | 10 - 40 | 10 - 40 | 10 - 40 | 20 - 40 |
| Release Range | AT | 4 - 20 | 6 - 25 | 7.5 - 30 | 6 - 25 |
| Contact Rating (max) |
W / VA |
10.0 | 10.0 | 10.0 | 10.0 |
| Switching Current (max) |
A |
0.5 | 0.5 | 0.5 | 0.5 |
| Carry Current (max) |
A |
1.5 | 1.5 | 1.5 | 1.5 |
| DC Switching Voltage (max) |
V DC |
180 | 180 | 180 | 180 |
| AC Switching Voltage (max) |
V AC |
130 | 130 | 130 | 230 |
| Breakdown Voltage (min) |
V DC |
200 | 200 | 200 | 280 |
| Initial Contact Resistance (max) |
mΩ |
100 | 120 | 150 | 150 |
| Insulation Resistance (min) |
Ω |
1011 |
1011 |
1011 |
1011 |
| Capacitance (min) |
Pf |
0.2 |
0.2 |
0.2 |
0.2 |
|
Operate Time (max) |
ms |
0.5 |
|
Bounce Time (max) |
ms |
0.15 |
|
Release Time (max) |
ms |
0.15 |
|
Resonance Frequency |
Hz |
> 2000 |
|
Operating Frequency (max) |
Hz |
500 |
|
Operating Temperature |
°C |
-40 to +200 |
| Shock Resistance (½Sin wave for 11ms) | g | 50 |
| Vibration Resistance (10-2000Hz) | g | 20 |
|
Measurement Test Coil |
717 102 002 |
SM-1322-(Sub Code)-(Start Operate AT)-(Finish Operate AT)
Please check our AT band FAQ for help on release AT codes
SM-1322-H-10-13
Denotes 10-13 Operate AT band with a minimum Release AT of 7.5
Lower Static Contact Resistance
Dynamic Contact Resistance Limit
Higher Insulation Resistance
Special Release Limits
Gold plated leads
|
|
|
Miniature |
|
|
|
|
Reed Relays and Electronics India Limited, 2008