TRS-P Thermal Reed Sensor for AC Loads
Features
Temperature range of 25°C to 130°C. Less than 3°C tolerance. Normally Closed Contact. Can be used up to 30W loads.
Description
These thermal reed sensors can accurately monitor temperature within 2-3C and are suitable for a wide range of applications. The load switching capability is that of the reed switch used, which is 30W. As these are a direct replacement to bimetallic strips, these themal reed sensors are only available in a normally closed, form B type contact, which opens when the configured temperature is reached.
Electrical
Contact Form | B | |
Temperature Tolerance | °C | ±3 |
Contact Rating (max) | W/VA | 30.0 |
Switching Current (max) | A | 1.0 |
Carry Current (max) | A | 2.0 |
DC Switching Voltage (max) | VDC | 230 |
AC Switching Voltage (max) | VAC | 230 |
Breakdown Voltage (min) | VDC | 350 |
Contact Resistance (max) | mΩ | 150 |
Insulation Resistance (min) | Ω | 109 |
Capacitance (typ) | pF | 0.2 |
Miscellaneous
Operate Time (max) | ms | 0.35 |
Bounce Time (max) | ms | 0.30 |
Release Time (max) | ms | 0.15 |
Resonance Frequency (typ) | Hz | >2000 |
Operating Frequency (max) | Hz | 1 |
Operating Temperature Range | °C | -20 to Cutout +20 |
Shock Resistance (½Sin wave for 11ms) | G | 50 |
Vibration Resistance (10-2000 Hz) | G | 20 |
Ordering Code
TRS-P-(Cut out temperature)-(Cable length in mm)-(Cable Termination Code)
Cut-out Temperature Range | °C | 25-130 |
Cable Termination Code | Termination Type |
S | Stripped to 5.0 mm |
T | Stripped and Tinned |
TRS-P-50-500-S denotes TRS-P Normally Closed Thermal Reed Sensor with a release of temperature of 50°C, having 500 mm cable length with Stripped ends.
Other Special Configurations: Lower Static Contact Resistance.
Usage Notes
Here are some of the recommended usage notes to ensure maximum durability of this product. The complete usage notes are available here.
Product Handling
![]() | Reed Switches, Reed Sensor and Magnet Sensors are sensitive devices that easily develop micro...Continue reading |
Ferro-magnetic parts
![]() | Using Ferro-magnetic mounting parts or screws within a 100 mm vicinity of a reed switch will...Continue reading |
Cable Handling
![]() | Cables with higher strands should be used so that there is minimal work hardening...Continue reading |
Reed Contact Protection Circuits
![]() | When a reed switch is to be connected to an inductive load or a...Continue reading |
Applications
Although we can never restrict the use of a reed sensor to a particular field, the following is a list of some of the applications that the TRS-P Thermal Sensor is known to perform well.
Thermal Reed Switches in Aquariums for controlling Water Temperature
![]() | Due to their accurate temperature cut-in and cut-out, Thermal Reed Switches can maintain an...Continue reading |
Thermal Reed Sensors for Sensing Temperature on Boats
![]() | Thermal reed sensors can also be used in a variety of applications on boats...Continue reading |
Thermal Reed Switches in Rice Cookers
![]() | After rice has cooked, rice cookers need to keep the rice warm at say,...Continue reading |