Actuation Distances for MS-108 Reed Sensors

Operate and release distances for the MS-108 reed sensor in the two standard AT bands when actuated with standard magnets are listed below. All distances given are in mm, with tolerances of ±0.5mm. Although some of the AT band / magnet combinations will produce similar actuating distances, selecting the right AT band and magnet for an application is important and can be done by going through our AT band FAQ and our magnet selection guide.

Actuation Distances for MS-108 Gull-wing SMD

RRE MS-105 magnet actuation
Magnet Actuation Direction

Operate Band 10-15 (AT)

MagnetDimensionsOperate DistanceRelease Distance
NDR-T4.0 x 1.5 x 1.52.0 – 3.53.5 – 4.0
NDR-S6.0 x 2.5 x 2.57.0 – 10.09.0 – 11.0
NDR-M8.0 x 3.0 x 3.011.0 – 14.014.0 – 15.0
NDR-I12.0 x 3.5 x 3.515.0 – 19.018.0 – 20.0
NDR-L19.0 x 4.0 x 4.021.0 – 27.024.0 – 29.0
NDC-TØ2.0 x 4.02.5 – 4.04.0 – 4.5
NDC-SØ3.0 x 7.09.0 – 12.011.0 – 13.0
NDC-MØ4.0 x 10.014.0 – 18.017.0 – 19.0
NDC-IØ6.0 x 12.024.0 – 28.027.0 – 30.0
NDC-LØ8.0 x 15.031.0 – 39.037.0 – 42.0

Operate Band 15-20 (AT)

MagnetDimensionsOperate DistanceRelease Distance
NDR-T4.0 x 1.5 x 1.51.0 – 2.02.0 – 3.5
NDR-S6.0 x 2.5 x 2.55.0 – 7.06.0 – 9.0
NDR-M8.0 x 3.0 x 3.09.5 – 11.011.0 – 14.0
NDR-I12.0 x 3.5 x 3.512.5 – 15.015.0 – 18.0
NDR-L19.0 x 4.0 x 4.019.0 – 21.022.0 – 24.0
NDC-TØ2.0 x 4.02.0 – 2.53.0 – 4.0
NDC-SØ3.0 x 7.07.5 – 9.09.0 – 11.0
NDC-MØ4.0 x 10.011.5 – 14.013.0 – 17.0
NDC-IØ6.0 x 12.020.0 – 24.023.0 – 27.0
NDC-LØ8.0 x 15.027.0 – 31.030.0 – 37.0

Operate Band 20-25 (AT)

MagnetDimensionsOperate DistanceRelease Distance
NDR-T4.0 x 1.5 x 1.50.5 – 1.02.0 – 3.0
NDR-S6.0 x 2.5 x 2.54.0 – 5.06.0 – 7.0
NDR-M8.0 x 3.0 x 3.08.0 – 9.510.0 – 11.0
NDR-I12.0 x 3.5 x 3.517.0 – 19.022.0 – 23.0
NDR-L19.0 x 4.0 x 4.011.0 – 12.515.0 – 16.0
NDC-TØ2.0 x 4.01.0 – 2.03.0 – 4.0
NDC-SØ3.0 x 7.06.0 – 7.59.0 – 9.5
NDC-MØ4.0 x 10.010.0 – 11.513.0 – 14.0
NDC-IØ6.0 x 12.018.0 – 20.023.0 – 24.0
NDC-LØ8.0 x 15.025.0 – 27.030.0 – 32.0

Ampere Turn Selection for your Application

Ampere Turn Selection Selecting the appropriate Ampere Turn (AT) or magnetic sensitivity for a Reed Switch, Reed Sensor, or Magnet Sensor is crucial in any Continue reading ->

Jul 24, 2024

Magnet Usage Best Practices

Magnet storage Rectangular Magnets Proper storage and magnet usage are critical to maintain their performance and prevent unintended hazards. Each Continue reading ->

Jun 17, 2024

Actuation Zones of a Reed Switch

Magnetic characteristics of a reed switch The following examples show typical actuation zones of a reed switch when actuated with a magnet from various axes. Generally, when a reed Continue reading ->

Jul 24, 2024

Magnet Information and Selection

Magnet Information In general magnet information, there are four families of magnets available commercially. Factors such as operating temperature, Continue reading ->

Jul 24, 2024