Data Center Cooling System Monitoring Using Flow Switches

Data centers are the backbone of digital operations, hosting servers that power websites, applications, and critical services. During peak usage hours, CPUs handle numerous processes simultaneously, generating significant heat. As CPUs get hotter, their performance drops, slowing down processes and potentially causing websites or applications to load more slowly. This latency can frustrate users, leading to customer dissatisfaction and potential revenue loss for companies reliant on fast digital interactions.
Effective CPU cooling is needed for maintaining optimal server performance in data centers. Cooling systems rely on consistent water flow to dissipate heat from CPU and other heat sinks, ensuring stable temperatures and uninterrupted operation. Monitoring the flow rate of this cooling water is essential to ensure the system functions effectively. If the cooling water flow decreases or stops, CPU temperatures can spike, leading to throttling, downtime, or even hardware damage. Continuous monitoring ensures that any disruption in cooling is immediately detected and addressed before impacting data center operations.
Reed switch-based flow switches offer a reliable solution for monitoring water flow in data center cooling systems. These switches operate on a paddle mechanism, where a spring-loaded paddle is placed in the water flow path. When water flows at the required rate, it pushes the paddle against the spring, moving a magnet attached to the paddle into proximity with the reed switch. This keeps the reed switch activated, signalling that cooling water is flowing properly. If the flow rate slows or stops, the paddle moves the magnet away from the reed switch. This change triggers an alarm, alerting operators to investigate and resolve the issue promptly.
Reed switch-based flow switches are durable, energy-efficient, and highly responsive, making them ideal for data center cooling systems. By providing real-time monitoring of water flow, they help prevent overheating, ensuring the smooth operation of servers and minimising the risk of downtime.
Application Classification
Applications are classified as Position Sensing, Pulse Counting, Electromagnetic or Relay, Temperature Sensing or Magnet Biasing types. This application is classified as follows and the link gives more information on best practices to help select the most suitable AT band and matching magnet.
Position sensing Type
![]() |
When an application requires the end position of a movement sensed, or the sensing of a part when it comes into a zone, or when the
Continue reading
Mar 21, 2025 |
Recommended Products
The Reed Switches and Sensors used in Flow Switch applications need to be robust, durable and efficient in meeting a high life expectancy. Our engineers work hard in life testing our products under various conditions, and our intention is to ensure end product durability and life. Although we wouldn’t want to restrict any of our products for use in only certain applications, the recommended products for use in this application are listed below.
Off-Centre Contact Reed Switch, MO-1422
![]() |
MO-1422 Miniature Off-Centre Contact Reed Switch with Full Length LeadsMO-1422 Miniature Off-Centre Contact Reed Switch with Cropped
Continue reading
Dec 2, 2024 |
Close Differential Reed Switch, MC-1425
![]() |
MC-1425 Close Differential Reed Switch with Full Length LeadsMC-1425 Close Differential Reed Switch with Cropped LeadsMC-1425 Close
Continue reading
Dec 2, 2024 |
Line Voltage switching Reed Switch, LV-1925
![]() |
Full Length LeadsCropped LeadsSMD Formed LeadsVertical MountingHorizontal Mounting starFeaturesContact Rating Configurable. Ruthenium
Continue reading
Dec 2, 2024 |