Line Voltage switching Reed Switch, LV-1925
Features
Contact Rating Configurable. Ruthenium contact. Robust 20.0 mm Glass. Normally Open. Inert gas filled.
Benefits
Omni-polar. Does not require power for operation. Sputtered Contact. RoHS Compliant. Not ESD Sensitive.
📝Description
The LV-1925 Line Voltage Reed Switch is engineered to excel in applications requiring robust endurance for switching line voltage loads up to 230V. Available in two versions capable of handling 30W and 60W loads respectively at 230V, it ensures reliable operation in environments where high voltage switching is necessary. With appropriate contact protection, it supports direct switching of tungsten filament lamps, making it suitable for lighting control and similar applications where precise and dependable operation is critical.
The cropped version of the LV-1925 Line Voltage Reed Switch is tailored for integration into smaller plastic housings, offering compactness and versatility for various installation requirements. It facilitates direct soldering onto cables, simplifying assembly processes and ensuring secure electrical connections. In PCB assembly, the SMD variant supports efficient integration through reflow soldering techniques, enhancing manufacturing throughput and reliability. Additionally, vertical and horizontal mount versions accommodate through hole PCB configurations, providing flexibility in installation orientation to suit different project specifications.
These design features collectively position the LV-1925 Line Voltage Reed Switch as a dependable choice across industries such as lighting controls, HVAC systems, and industrial automation. Its capability to handle high voltage loads, coupled with versatile mounting options and robust construction, ensures consistent performance and durability in demanding applications. Whether deployed in commercial settings or industrial environments, this reed switch delivers reliable switching solutions, meeting the stringent requirements of modern electrical and electronic systems.
Magnets for Actuating Reed Switches and Reed Sensors
![]() |
Drawing of Cylindrical MagnetsDrawing of Rectangular Bar Magnets starFeaturesNdFeB High Energy. Nickel coated. Energized
Continue reading
Sep 3, 2024 |
Actuation Distances for LV-1925 Formed Reed Switch
![]() |
For easy selection of AT band and Magnet for an application, we offer Actuation distances for the LV-1925 Reed Switch in cropped, SMD,
Continue reading
Sep 3, 2024 |
⚡️Electrical
Contact Form | A | |
Contact Rating (max) | W/VA | 60.0 |
Switching Current (max) | A | 0.5 |
Carry Current (max) | A | 2.5 |
DC Switching Voltage (max) | VDC | 230 |
AC Switching Voltage (max) | VAC | 230 |
Breakdown Voltage (min) | VDC | 350 |
Contact Resistance (max) | mΩ | 100 |
Insulation Resistance (min) | Ω | 1011 |
Capacitance (typ) | pF | 0.2 |
📊Miscellaneous
Operate Time (max) | ms | 1.0 |
Bounce Time (max) | ms | 0.60 |
Release Time (max) | ms | 0.15 |
Resonance Frequency (typ) | Hz | >2000 |
Operating Frequency (max) | Hz | 300 |
Operating Temperature | °C | -40 to +200 |
Shock Resistance (½Sin wave for 11ms) | G | 50 |
Vibration Resistance (10-2000Hz) | G | 20 |
Test Coil Number | 717 102 002 |
⚙️Ordering Code
LV-1925-(Contact Rating Code)-(Operate Band)-(Formation Code)
Contact Rating Code | L | M | |
Corresponding Wattage | W/VA | 30 | 60 |
Operate Band | AT | 20-50 | 30-60 |
Corresponding Release Band | AT | 5-20 | 10-30 |
Formation Code | Lead Type |
Full Length Leads | |
C | Cropped |
S | SMD |
H | Horizontal Mount |
V | Vertical Mount |
Examples: LV-1925-L-20-25 denotes 30 W contact rating in 20-25 Operate Band (AT) with Full Length leads. LV-1925-M-30-38-V denotes 60 W contact rating in 30-38 Operate Band (AT) with Leads cropped and welded for Vertical Mounting.
Other Special Configurations: Lower Static Contact Resistance, Dynamic Contact Resistance Limit, Higher Insulation Resistance, Special Release Limits, Gold plated leads.
🛠️Usage Notes
Here are some of the recommended usage notes to ensure maximum durability of this LV-1925 Line Voltage Reed Switch. The complete usage notes are available here.
Ampere Turn Selection for your Application
![]() |
Selecting the appropriate Ampere Turn (AT) or magnetic sensitivity for a Reed Switch, Reed Sensor, or Magnet Sensor is crucial in any
Continue reading
Jul 24, 2024 |
Handling of Reed Switches
![]() |
Handling of Reed Switches Reed Switches, Reed Sensors, and Magnet Sensors are delicate devices prone to developing micro cracks in
Continue reading
Jun 17, 2024 |
Soldering of Reed Switches
![]() |
Soldering Reed Switches and Reed Sensors requires meticulous handling to safeguard these delicate components against inadvertent damage.
Continue reading
Jun 17, 2024 |
Ferro-magnetic Parts
![]() |
Reed Switches utilize a nickel-iron alloy, sputter coated with additional Ruthenium to render it ferromagnetic while maintaining low
Continue reading
Jun 17, 2024 |
Encapsulation and Potting
![]() |
Encapsulation Nozzle When potting or encapsulating reed switch assemblies in custom housings, the choice of materials plays a critical
Continue reading
Jun 17, 2024 |
Protection Circuits for Reed Switches
![]() |
It is assumed that the ideal reed switch load is a Resistive Load, but it is almost impossible to reduce any load to purely resistive.
Continue reading
Jun 17, 2024 |
🧰Applications
Although we can never restrict the use of a reed switch to a particular field, the following is a list of some of the applications that the LV-1925 Line Voltage Reed Switch is known to perform well.
Treadmill Safety Using Reed Switches
![]() |
Treadmill safety is important and accidents are a common concern in gyms and home fitness settings, especially when the belt continues
Continue reading
Jul 14, 2025 |
Ice Maker Water Level Monitoring using Reed Sensors
![]() |
Ice makers—whether standalone units or integrated into refrigerators—require a steady water supply to ensure ice does not run out.
Continue reading
Jun 25, 2025 |
Data Center Cooling System Monitoring Using Flow Switches
![]() |
Data centers are the backbone of digital operations, hosting servers that power websites, applications, and critical services. During
Continue reading
Dec 13, 2024 |
Distilled Water Level Monitoring in Batteries Using Reed Switches
![]() |
In the solar power industry, traditional lead-acid batteries that require distilled water are highly regarded for their longevity and
Continue reading
Dec 6, 2024 |
Ballast Tank Level Sensing on Commercial Submarines
![]() |
In commercial submarines, ballast tanks help in controlling buoyancy to allow the vessel to submerge or surface. These tanks take in
Continue reading
Oct 25, 2024 |
Automatic Gates Use Magnet Sensors for Motor Control
![]() |
Automatic gates are a common feature in gated compounds, providing security and convenience. Traditionally, these gates are operated by
Continue reading
Sep 11, 2024 |
Chill Water Flow Sensing Using Reed Switches
![]() |
In industrial equipment, such as sputtering machines, maintaining optimal temperatures for critical components is paramount. Specific
Continue reading
Sep 3, 2024 |
Automatic Doors’ Position Detection Using Reed Sensors
![]() |
Traditionally, doors in shopping malls, commercial buildings, and offices required manual intervention for operation. Users had to
Continue reading
Sep 3, 2024 |
Fire safety Emergency Doors Use Magnet Sensors
![]() |
Fire safety building codes provide standards for the safety, welfare and general health of the personnel occupying the buildings. This
Continue reading
Sep 3, 2024 |
Float Switches in Portable Air Conditioners
![]() |
Air Conditioners remove heat and moisture from an occupied space thereby improving the comfort of the occupants. The air conditioning of
Continue reading
Sep 3, 2024 |
Exhaust Emissions Sensing Using Reed Switches
![]() |
Pollution, characterised by greenhouse gases and smog, significantly contributes to global warming, underscoring the critical importance
Continue reading
Sep 3, 2024 |
Magnet sensors in Top-loading Washing Machines
![]() |
Traditional top-loading Washing Machines have some advantages over the front-loading ones. One does not need to bend down so much during
Continue reading
Sep 3, 2024 |
Welding Machines Use Magnet Sensors to detect Current Flow
![]() |
Welding machines come in two main types: Constant Current and Constant Voltage. In Constant Current welding machines, the output voltage
Continue reading
Sep 3, 2024 |
High Voltage Relays are Built with multiple Reed Switches
![]() |
Within the power industry, a diverse array of high voltage reed relays serves crucial roles in signal and current switching across single
Continue reading
Sep 3, 2024 |
Bridge control in Airports Use Magnet Sensors
![]() |
In airports, as the boarding bridge approaches within a critical meter of the door, meticulous adjustments are necessary to ensure a
Continue reading
Sep 3, 2024 |
Extensometers Use Reed Switches for Depth Checks
![]() |
Deep excavations preceding construction projects require careful monitoring to ensure safety. Settlement depths must be observed before
Continue reading
Sep 3, 2024 |
Reed switches and Float switches in Water tank control
![]() |
Water scarcity is a pressing issue in many urban areas worldwide, emphasizing the importance of efficient water management systems,
Continue reading
Sep 3, 2024 |
Adjustable Chairs Use Magnet Sensors for Assessing extents
![]() |
Motorized adjustable chairs are indispensable in settings like dentists' offices, massage parlours and hair-cutting salons, providing
Continue reading
Sep 3, 2024 |
Explosive Areas Need Reed Switches to safely switch Circuits
![]() |
Explosive areas use special enclosures that are essential components across various industries such as petroleum, gas, chemical, mining,
Continue reading
Sep 3, 2024 |
Fork Lifts and Hoists Use Magnet Sensors for End-position Sensing
![]() |
The hydraulic pistons and cylinders that drive hoists and fork lifts rely on precise positioning for optimal performance.
Continue reading
Sep 3, 2024 |
Liquid detection Probes Use Reed Switches
![]() |
Boring holes in the ground serves various purposes, such as extracting water, gases, or conducting geological and environmental
Continue reading
Sep 3, 2024 |
Wind Vanes Use Reed Switches for Direction Sensing
![]() |
A weather vane, a timeless instrument, serves the vital purpose of indicating wind direction. Its simple yet effective design typically
Continue reading
Sep 3, 2024 |
Underwater currents in Lakes measured using Flow Meters
![]() |
The dynamics of underwater currents in lakes and other aquatic ecosystems are influenced by a multitude of factors, ranging from
Continue reading
Sep 3, 2024 |
Survival Rafts and ELTs Using Reed Sensors
![]() |
Survival rafts are equipped with sophisticated water sensors designed to activate the compressed air cylinder, inflating the raft
Continue reading
Sep 3, 2024 |
Hatch, Anchor and Rudder Position-Sensing Using Reed Sensors
![]() |
Hatch, anchor and rudder positions on boats and yachts need to be monitored. In the realm of advanced sailboats and yachts, the
Continue reading
Sep 3, 2024 |
Anti-lock braking system (ABS) Use Reed Sensors
![]() |
The Anti-lock Braking System (ABS) represents a pivotal safety feature utilized not only in vehicles but also in aircraft. In the realm
Continue reading
Sep 3, 2024 |
Defective lamp detection Using Reed Switch based Relays
![]() |
In modern automobiles, the integration of advanced sensor technology enables the provision of a diverse array of critical information
Continue reading
Sep 3, 2024 |
Reed Relays control Multiple Automobile circuits
![]() |
Reed Relays are integral components in various automotive electronics applications, serving critical functions such as signal switching
Continue reading
Sep 3, 2024 |
Food Processors and Mixers Use Current Sensing Relays
![]() |
Food Processors use current sensing Reed Relays to trigger an output when the coil current exceeds a set, designed-in point. Reed Relays
Continue reading
Sep 3, 2024 |
Reed switches in Instant Water heaters and Power showers
![]() |
Bathrooms appliances such as Instant Water Heaters and power showers use reed switch based Flow switches to detect if the water supply
Continue reading
Sep 3, 2024 |
Rice Cooker Temperature Sensing Using Reed Switches
![]() |
A Rice Cooker is a kitchen appliance used to boil rice and continue to keep the rice warm and hydrated. As more heat is required to boil
Continue reading
Sep 3, 2024 |
Commercial Coffee Machines Use Reed Sensors
![]() |
Commercial coffee machines and tea vending machines are built with durability in mind as the number of cups served per day could exceed
Continue reading
Sep 3, 2024 |
Fluid Metering Using Reed Sensors
![]() |
In many major cities, utility companies or gated communities manage the distribution of piped water and Liquefied Petroleum Gas (LPG) to
Continue reading
Sep 3, 2024 |
Reed switches in Reed Relays for Fax Machines
![]() |
A Facsimile Machine or Fax Machines enable the transmission of documents over telephone lines. Although these machines gained maximum
Continue reading
Sep 3, 2024 |